Chemical Plug With Ampoule RM II FISCHER
Characteristics:
- For fixing in concrete or hard natural stone
- High loads with anchor bolts RG M and sleeve with internal thread RG MI
- Also fire certified
- Fastening without mechanical expansion near edges
- Ampoule application time of RM II resin
Ampoule application time of RM II resin
| base material temperature |
Curing time |
| -15 °C - - 10 °C |
30 hours |
| - 9 °C - - 5 °C |
16 hours |
| - 4 °C - ± 0 °C |
10 hours |
| ± 1 °C - ± 5 °C |
45 minutes |
| + 6 °C - +10 °C |
30 minutes |
| + 11 °C - + 20 °C |
20 minutes |
| + 21 °C - + 30 °C |
5 minutes |
| + 31 °C - + 40 °C |
3 minutes |