Chemical Plug With Ampoule RM II FISCHER
Characteristics:
- For fixing in concrete or hard natural stone
- High loads with anchor bolts RG M and sleeve with internal thread RG MI
- Also fire certified
- Fastening without mechanical expansion near edges
- Ampoule application time of RM II resin
Ampoule application time of RM II resin
base material temperature |
Curing time |
-15 °C - - 10 °C |
30 hours |
- 9 °C - - 5 °C |
16 hours |
- 4 °C - ± 0 °C |
10 hours |
± 1 °C - ± 5 °C |
45 minutes |
+ 6 °C - +10 °C |
30 minutes |
+ 11 °C - + 20 °C |
20 minutes |
+ 21 °C - + 30 °C |
5 minutes |
+ 31 °C - + 40 °C |
3 minutes |